Leica AP20 Specifications
POLEHEIGHT
Accuracy in height | At snap-lock position | =/- 1.0mm |
TILT COMPENSATION
Additional pole tip uncertainty1 for tilt down to 90°, typically
Target height (m) | Horizontal (2D) | Vertical (1D) | |
0.228* | 1 mm + 0.1 mm/° tilt | 1 mm + 0.05 mm/° tilt | |
1.600 | 3 mm + 0.6 mm/° tilt | 1 mm + 0.05 mm/° tilt | |
2.000 | 4 mm + 0.7 mm/° tilt | 1 mm + 0.1 mm/° tilt | |
Tilt range2 | +/- 180° | ||
Range to total station3 | Typically 300 m |
TARGETID
Number of different IDs | 16 | ||
Working range | Typically 150 m |
GENERAL
Power management | Exchangeable Lithium-Ion battery (GEB321) | Operating time up to 16 h for AP20 H / AP20 ID and 6 h for AP20 T / AP20 | |
Weight | AP20 including battery | 0.5 kg (1.1 lbs) | |
Power management | Working temperature range Storage temperature range Dust & Water (IEC 60529) / Humidity | -30°C to +60°C (-22°F to 140°F) -40°C to +80°C (-40°F to 176°F) IP67 / 95%, non-condensing |
LEICA AP20 AUTOPOLE VARIANTS
AP20H | AP20ID | AP20 T | AP20 | |
PoleHeight | √ | X | √ | √ |
Tilt Compensation4 | X | X | √ | √ |
TargetID5 | X | √ | X | √ |
LEICA AP REFLECTOR POLE VARIANTS
GLS516 | GLS51 F7 | CRP46 | CRP57 | |
Surveying, stub interface | √ | √ | X | X |
Construction, 5/8″ screw interface | X | X | √ | √ |
Snap lock position every | 5 cm | 0.2 ft | 5 cm | 1.0 ft |
√=Standard X=Not available
1. Measurement precision, accuracy, reliability and time for initialisation are dependent
upon various factors including angular and distance accuracy of the total station,
target type, atmospheric conditions, target height and level of pole tilt.
2. Free line of sight to target required
3. Using radio handle RH18 or CCD18, connected to CS20 with internal LR-BT
4. Requires total station with target lock functionality and radio handle RH18 or CCD18
5. Requires total station with PowerSearch functionality
6. Metric scale
7. Feet scale
* 0.228 m refers to height with CRP10 attached to GRZ122